Power-converters or amplifiers are required to drive high power piezoelectric transducers and attached processing equipment, at the optimum resonance mode. Oct 10, 2012 - Try these linear amplifiers made by Apex. They are designed specifically for ultrasound aplications. Enter image description here.
Hi MM, I used a 'burst' method of driving 200KHz and 30KHz transducers. The transducer pulse generator was from a square wave osc, tunable over a narrow range in order to get the optimum power out from the transducer. The pulse or burst width generator was adjustable from 100uSec thru 10mSec, this enabled a level of power control in the acoustic pulse. The transducer driver stage was a NPN power transistor driving a 1:3 or 1:5 transformer at 30KHz or 200KHz respectively, supply voltage 12V or 24V depending upon the required acoustic power.
Esplora; Accedi; Crea un utente; Pubblicare ×. Prva operska predstava u obnovljenoj Operi Narodnog pozorišta, Evgenij Onegin P. Čajkovskog, Beograd, 17. Februar 1945, Muzej pozorišne umetnosti Srbije, Zbirka plakata. Oltre che nell’ambito della grammatica očerki [Il lessico e la fraseologia dell’Evgenij Onegin: schizzi ermeneutici] (Jazyki slavjanskoj kul’tury, Moskva, 2008).
My product applications were for hydro-graphic depth echo sounders, working in water depths of 0.5mtr upto 400mres. E Is you application bio-diesel.? Hi Eric, Isn't the number of cycles (burst) of 40khz determined by the length of the ON pulse? A 20ms pulse will have more cycles that a 2ms one (10 times more). The size of the Burst is directly related to the duty cycle. In order to increase the burst time, we need an amplifier that will take more power.
Currently I can't get past a duty cycle of 1% without smoking the heatsinked Fet. EG: 5ms ON and 500mx OFF. Chemwindow software free download.
As I mentioned before, I dip all transducers to find their exact resonant TX frequencies and their band pass. Then I program the CPU to change frequency over the band pass. If the BP is say 2khz wide, I will step the frequency up by 100hz every few seconds.
That way I send multiple bursts to 20 different frequency locations, of which a few should be more effective in ringing the wafer. What do you think? I built a cat scarer at my last house.
I didn't bother with trying to tune to the ultrasonic horn I had. I drove the secondary of a toroidal mains transformer using a low voltage drive at ~41KHz and used the primary straight across the piezo horn. Maybe not the most efficient, but it worked effectively and gave quite a nip when touched. What surprised me most was the frequency response of a 6.0.6-240VAC cheapo toroid was at such a frequency.